Every concrete order comes down to three numbers: strength, slump and water-cement ratio. Get them to work together and the pour goes well. Let them drift apart and you get cracks, scaling and cylinder breaks that miss f'c. This guide explains the basics of concrete mix design for engineers, builders and homeowners, in US units with SI in parentheses.
Water-cement ratio (w/cm): the number that drives durability
NRMCA defines w/cm as the weight of the mixing water divided by the weight of all cementitious materials (NRMCA CIP 44). Cementitious materials include portland cement plus supplementary cementitious materials (SCMs) such as fly ash, slag cement and silica fume. That is why the older term "water-cement ratio" is now written w/cm.
Concrete with low permeability to water and dissolved chemicals is generally durable, and permeability is affected by w/cm and by the type and amount of cementitious materials. SCMs reduce permeability compared with mixtures that contain only portland cement (CIP 44). Strength follows the same trend. For a given set of materials there is a unique relationship between w/cm and strength, and the relationship shifts with air entrainment and with the size and type of coarse aggregate (NRMCA FAQ).
What ACI 318 requires for w/cm and strength
ACI 318 assigns an exposure class to each concrete member and requires a maximum w/cm and a minimum specified strength, f'c, for the classes that need them. NRMCA summarizes the requirements as follows (CIP 44).

| Exposure class | Max w/cm | Min f'c (psi) |
|---|---|---|
| F0, S0, W0, C0, C1, W1 | None | 2,500 |
| F1 | 0.55 | 3,500 |
| S1, W2 | 0.50 | 4,000 |
| S2, F2, F3 (plain concrete) | 0.45 | 4,500 |
| C2, F3 (reinforced concrete) | 0.40 | 5,000 |
Class F covers freezing and thawing, S covers sulfates, C covers corrosion protection of reinforcement, and W covers contact with water. Vertical members, footings and foundations are typically assigned class F1 (CIP 44). Your project specifications and the locally adopted code govern the actual class. For what the f'c numbers mean in testing, see our guide to concrete compressive strength.
One practical point: w/cm cannot be verified when concrete is delivered, so strength tests become the basis of acceptance (CIP 44). NRMCA also advises not specifying a maximum w/cm where it is not needed, because the same w/cm can perform differently with different cementitious materials (NRMCA FAQ).
Slump: what it tells you and what it does not
Slump, measured by ASTM C143, describes the consistency or fluidity of a concrete mixture. It matters to the contractor because it affects the ability to place, consolidate and finish the concrete. NRMCA cautions that slump is not a good measure of water content in batches that contain admixtures (NRMCA TIP 12).
Slump also falls with time. Mixing water is used up by aggregate absorption, cement hydration and evaporation, and delivery times can range from 45 to 90 minutes (TIP 12). A mix therefore has to be designed to hit the target slump at the jobsite, not at the plant.
Admixtures and air content
Water reducers let you get higher slump without adding water, or lower the water content for the same slump, which raises strength (NRMCA CIP 15). Air-entraining admixtures create microscopic bubbles that protect against freezing and thawing and deicing salts. For exterior flatwork exposed to those conditions, NRMCA gives an air content of 4% to 7% depending on aggregate size. In concrete with higher cementitious content, each 1% of air reduces strength by about 5%. Air entrainment is not needed for interior structural concrete, and it should be avoided on flatwork that will get a smooth troweled finish (CIP 15).
Worked example: how much jobsite water is too much?
Take a mix with 280 lb of water and 560 lb of cementitious material per cubic yard. The w/cm is 280 ÷ 560 = 0.50. The member is in class F1, so the ACI 318 maximum is 0.55.
NRMCA gives a rule of thumb: about 1 gallon of water per cubic yard raises slump by about 1 inch (NRMCA CIP 26). Water weighs 8.34 lb per gallon, so each added gallon per cubic yard adds 8.34 lb to the numerator.
- Add 3 gal/yd³: (280 + 25.0) ÷ 560 = 0.545. Still under 0.55, and slump rises about 3 in.
- Add 4 gal/yd³: (280 + 33.4) ÷ 560 = 0.560. Over the limit.
- The most you can add is (0.55 × 560 − 280) ÷ 8.34 = 3.4 gal/yd³.

Note that the design water in the mix was already 0.50, so there was only a small allowance. If the design had been 0.55 to begin with, no jobsite water at all could be added.
Rules for adding water at the jobsite (ASTM C94)
NRMCA summarizes the ASTM C94 conditions (CIP 26). Water may be added only if the specified slump or w/cm is not exceeded. Add it before any significant quantity of concrete has been discharged. Measure it and have the purchaser's representative initial the delivery ticket. Turn the drum 30 more revolutions at mixing speed afterward. Once some concrete is discharged, no more water may be added. Check slump on a preliminary sample taken after the first 0.25 yd³ is discharged, and treat it as a consistency check, not an acceptance test (NRMCA CIP 41).
Water beyond the design amount delays setting, reduces strength, hurts durability and raises the chance of cracking (CIP 26). A water reducer or superplasticizer is the better choice for more slump, ideally agreed at a pre-pour conference.
Common mix design mistakes
- Adding "just a little" water to make finishing easier, without measuring or recording it.
- Ordering high slump with no water reducer, so the plant adds water to get there.
- Specifying a maximum w/cm for concrete that does not need one, which raises cost with no benefit.
- Ignoring delivery time and hot weather, so slump arrives well below target.
- Using entrained air on concrete that will be hard-troweled.
Mix design is only one piece of takeoff and ordering. See our guides to cubic yards of concrete for quantities and the construction takeoff for beginners for putting numbers on a project.
Frequently asked questions
What is the water-cement ratio?
It is the weight of mixing water divided by the weight of the cementitious materials. Engineers now write it w/cm because the denominator includes fly ash, slag cement and silica fume as well as portland cement. A mix with 280 lb of water and 560 lb of cementitious material has a w/cm of 0.50.
What is a good water-cement ratio for concrete?
It depends on the exposure. ACI 318 sets no maximum w/cm for dry interior concrete, 0.55 for class F1 freezing and thawing, 0.45 for class F2, and 0.40 for chloride exposure class C2 and reinforced concrete in class F3. Lower values give lower permeability, but the mix still has to be workable.
What does slump measure?
Slump, measured by ASTM C143, describes the consistency of fresh concrete. It tells you how easily the mix will flow and be placed. It is not a reliable measure of water content, especially when admixtures are used.
Can I add water to a ready-mix truck on site?
Only within limits. ASTM C94 allows it if the specified slump and w/cm are not exceeded, the water is measured, the drum is turned 30 more revolutions, and the quantity is recorded on the delivery ticket. Extra water beyond the design amount lowers strength and durability.
Does adding water make concrete stronger or weaker?
Weaker. For a given set of materials, more water per unit of cementitious material means a higher w/cm, which lowers strength and increases permeability. Water reducers are the better way to get more slump without that penalty.
Sources
- NRMCA, CIP 44 - Durability Requirements for Concrete: https://www.nrmca.org/wp-content/uploads/2021/01/44pr.pdf
- NRMCA, CIP 26 - Jobsite Addition of Water: https://www.nrmca.org/wp-content/uploads/2021/01/26pr.pdf
- NRMCA, CIP 15 - Chemical Admixtures for Concrete: https://www.nrmca.org/wp-content/uploads/2021/01/15pr.pdf
- NRMCA, TIP 12 - Slump Loss of Concrete: https://www.nrmca.org/wp-content/uploads/2020/04/TIP12w.pdf
- NRMCA, CIP 41 - Acceptance Testing of Concrete (ASTM C94 preliminary sample): https://www.nrmca.org/wp-content/uploads/2021/01/41pr.pdf
- NRMCA, Frequently Asked Questions on Concrete Materials (w/cm): https://www.nrmca.org/association-resources/research-and-engineering/frequently-asked-questions-on-concrete-materials/